Redefining
Immersion Cooling

SmartPodX

Immersion Cooling has never been so easy.

Simple.
Flexible.

More than 100kW per rack footprint.

Unrivaled Density.

Lorem ipsum lorem ipsum lorem ipsum lorem ipsum

SmartPods

Powered by the SmartCDU

The SmartPodX is the first patented immersion cooling solution to fully submerge the Cooling Distribution Unit (CDU) in the cooling fluid.
This incredible breakthrough allows for simple SmartCDU "cool-swap" without interrupting submerged hardware operations.

A single SmartPodX can be deployed with 1 or 2 CDU's, allowing for unrivalled resiliency by supplying 2 independent electrical and water feeds to each SmartCDU.

Submer also delivers a crane solution to easily extract and replace both SmartCDU's and IT Hardware without effort.

Simplified Deployment

SmartPods can be easily deployed indoor or outdoor with minimum facility requirements.
Submer's solution can be deployed by connecting to existing data center water loops or leveraging unrivalled PUE by using warm water loops that don't require chillers or compressors.


SmartPods can operate in any climate across the Globe without chillers. Hook them up to dry-coolers or adiabatic cooling towers and benefit from 90% savings in cooling costs with a full installation PUE < 1.03.

SmartPodX

Technical Specs

SmartPodXL
45 U / 42 OU
220 (L) x 85 (W) x 110 (H) cm
86.6 (L) x 33.5 (W) x 43.3 (H) inch
1450 kg / 3190 Ibs
1300l / 340 gallons
40-60°C / 104-140°F

SmartCDU

Facility requirements


IT Hardware capacity
Dimensions
Weight (Empty)
SmartCoolant capacity

IT Hardware capacity
Dimensions

Total weight (full of SmartCoolant)
SmartCoolant capacity
Typical SmartCoolant Setpoint
Water supply inlet temperature
Water flow rate
Warm water outlet temperature
Floor load capacity
Fire Suppression System
Temperature
SmartPodX
23 U / 21 OU
120 (L) x 85 (W) x 110 (H) cm
47.3 (L) x 33.5 (W) x 43.3 (H) Inch
850 kg / 1870 Ibs
650 l / 170 gallons


40-60°C / 104-140°F
Recommended <= 32°C / 89°F
Inhibitors and/or softeners: depending on environment icing and water quality conditions
9 - 11 m3/h / 39 gpm
Expected 37°C / 99°F
900 kg/sqm / 1980 Ibs (IT hardware not considered)
Standard air-cooled data center fire suppression system
-20°C to 55°C / -4°F to 131°F
SmartPodX
50 kW
750 W
1.015
2N / Tier III
SmartPodXL
50 kW
750 W
1.015
2N / Tier III

Heat dissipation capacity
Max power consumption
Mechanical Power Usage Effectiveness
Redundancy

Heat dissipation capacity
Max power consumption
Mechanical Power Usage Effectiveness
Redundancy

Heat dissipation capacity
Max power consumption
Mechanical Power Usage Effectiveness
Redundancy
Power supply
Power supply connection
Water supply connection
Monitoring
400 V 60 Hz /  208 V 60 Hz
Industrial connector three phase 3P+E+N 32A IEC 60309
1 1/2" BSPP Thread
+20 real-time metrics over public REST API / DCIM / Redfish compatible
SmartPodXL+
100 kW
1500 W
1.015
2N / Tier IV

Compatible with any IT Hardware

Contact

*By clicking 'Submit' you accept our Privacy Policy
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Considering Immersion Cooling? Get in touch with us!

Ask questions, tell us more about your upcoming datacenter/HPC or Hyperscale project. We're here to help.
contact@submer.com
Barcelona: +34 932 202 855
Palo Alto: +1-650-304-0654